OPERATION
EN
MACHINE APPLICATION
Use this machine to clean visible surface soils on a
daily basis or as needed to maintain a high level of
carpet cleanliness. The machine may be used during
normal business hours because often the carpet is dry
in less than 30 minutes.
If the carpet is heavily soiled, have the carpet deep
cleaned first before using this machine for routine
surface cleaning.
MACHINE SETUP
INSTALLING ROLLERS
FOR SAFETY: Before installing rollers, turn off
machine and unplug power cord from wall outlet.
1. Raise the scrub head off the floor with the support
stand and remove the roller idler plate (Figure 1).
Turn the idler plate locking knob counter--clockwise
to remove.
FIG. 1
2. Connect the two rollers to the drive hubs
(Figure 2).
FIG. 2
6
All manuals and user guides at all-guides.com
3. Connect the idler plate to the rollers and reinstall
NOTE: If storing the machine for an extended period,
raise the scrub head with kick stand to prevent a flat
spot in rollers.
FILLING SOLUTION TANK
1. Lift the cover and remove the solution tank from the
2. Fill the solution tank with 5 gal/19 L of clean water
ATTENTION: Do not add any cleaning detergents to
solution tank. Cleaning detergent must be pre--sprayed
on the carpet with the use of a pump--up sprayer.
ATTENTION: Do not use the recovery tank to fill
the solution tank. Dirt from the recovery tank may
cause damage to the solution pump.
Use or Pick Up Flammable Materials.
the idler plate. Make sure the idler plate hooks
engage the scrub head and that the locking knob is
secure (Figure 3).
FIG. 3
machine (Figure 4).
(122°F/50°C maximum temperature) (Figure 5).
Partially fill if unable to lift a full tank.
FIG. 4
WARNING: Fire Or Explosion Hazard, Do Not
Nobles Strive Compact (03- -08)
FIG. 5