TABLE 1 – GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC EMISSIONS
The Positively Clear Acne Clearing Blue Light is intended for use in the electromagnetic environment specified below.
The customer or the user of the Sapphire should assure that it is used in such an environment.
EMISSIONS TEST
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
*Meets Class B limits but is not intended for use in domestic establishments.
TABLE 2 – GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC IMMUNITY
The Positively Clear Acne Clearing Blue Light is intend ed for use in the electromagnetic environment specified below. The
customer or the user of the Positively Clear Acne Clearing Blue Light should assure that it is used in such an environment.
IMMUNITY TEST
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrical fast
transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
Power frequency
(60 Hz)
magnetic field
IEC 61000-4-8
COMPLIANCE
Group 1
Class B*
Not Applicable
Not Applicable
IEC 60601 TEST LEVEL
± 6 kV Contact
± 8 kV Air
± 2 kV Mains
± 1 kV I/Os
± 1kV Differential
± 2kV Common
>95% Dip for
0.5 Cycle
60% Dip for 5 Cycles
30% Dip for 25 Cycles
>95% Dip for 5 Seconds
3 A/m
ELECTROMAGNETIC ENVIRONMENT - GUIDANCE
The Positively Clear Acne Clearing Blue Light must emit
electromagnetic energy in order to perform its intended function.
Nearby electronic equipment may be affected when RF is
energized.
The Positively Clear Acne Clearing Blue Light is suitable for use
in all establishments, including domestic establishments and
those directly connected to the public low voltage power supply
network that supplies buildings used for domestic purposes.
The Positively Clear Acne Clearing Blue Light is suitable for use
in all establishments, other than domestic and those directly
connected to the public low voltage power supply network that
supplies buildings used for domestic purposes.
COMPLIANCE LEVEL
± 6 kV Contact
± 8 kV Air
± 2 kV Mains
± 1 kV I/Os
± 1kV Differential
±2 kV Common
>95% Dip for 0.5 Cycle
60% Dip for 5 Cycles
30% Dip for 25 Cycles
>95% Dip for 5 Seconds
3 A/m
ELECTROMAGNETIC
ENVIRONMENT - GUIDANCE
Floors should be wood, concrete
or ceramic tile. If floors are covered
with synthetic material, the relative
humidity should be at least 30%.
Mains power quality should be that
of a typical home environment.
Mains power quality should be that
of a typical home environment.
Mains power quality should be that
of a typical home environment.
If the user of the Positively Clear
Acne Clearing Blue Light requires
continued operation during
power mains interruptions, it is
recommended that the Positively
Clear Acne Clearing Blue Light be
powered from a battery.
Power frequency magnetic fields
should be at levels characteristic of
a typical location in a typical home
Tria Beauty 25