WARNING
Disconnect electrical supply before servicing the appliance.
When the flexible cord has to be changed it is necessary to follow the procedure descri-
bed hereafter:
- Turn off main gas shut-off valve and disconnect electrical supply
- Pull out entire cooktop from the counter by loosing the fixing brackets
- Disconnect gas supply connector from cooktop manifold
- Open un connecting terminal block cover, see fig. 2
- Open flexible cord lock and loosen the old cord prongs from terminal block
- Connect new flexible cord prongs to terminal block and fix flexible cord lock, remem-
bering that the earth wire (green) must be longer by one inch than the other ones. For
Line and Neutral wire connection, follow signs on terminal block
- The flexible cord must be hold tight by the cord lock, in such a way that it may not
be pulled out. The flexible cord path must not be in proximity or in contact with hot
surfaces that may damage the cord itself.
Fig. 2
ATTENTION: The flexible cord must be in accordance with National Electrical Codes and
suitable for the hob technical characteristics electrical ratings. A 18 AWG three-prong groun-
ding plug flexible cord, type SJT3x18AWG.
THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR IMPROPER INSTALLATION, ADJU-
STEMENT, ALTERATION, SERVICE, MAINTENANCE OR USE OF THE APPLIANCE, WHICH MAY
RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE.
Installation of this cooktop must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition.
In Canada the cooktop must be installed in accordance with the current CGA Standard
CAN/CGA-B149 - Installation Codes for Gas Burning Appliances and Equipment and/or
local codes.
GAS SUPPLY CONNECTION:
A TRAINED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CON-
NECTION.
Leak testing of the appliance shall be conducted by the installer according to the instructions
given in this section.
This appliance should be installed and used with the supplied pressure regulator. Inlet
GAS SUPPLY