10. Charger indicator
Indicator status
Red LED
Green LED
Off
Flashing
On
Off
Off
On
Flashing
Off
Flashing
Flashing
On
On
Anl_TC-AV_18-15_Li_C_SPK13.indb 20
Anl_TC-AV_18-15_Li_C_SPK13.indb 20
GB
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
Charging
The charger is charging the battery pack in quick charge mode. The char-
ging times are shown directly on the charger.
Important! The actual charging times may vary slightly from the stated
charging times depending on the existing battery charge.
The battery is charged and ready for use.
The unit then changes over to gentle charging mode until the battery is
fully charged.
To do this, leave the rechargeable battery on the charger for approx. 15
minutes longer.
Action:
Take the battery pack out of the charger. Disconnect the charger from the
mains supply.
Adapted charging
The charger is in gentle charging mode.
For safety reasons the charging is performed less quickly and takes more
time. The reasons can be:
- The rechargeable battery has not been used for a very long time.
- The battery temperature is outside the ideal range.
Action:
Wait for the charging to be completed; you can still continue to charge the
battery pack.
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20° C)
for one day .
- 20 -
04.03.2021 08:01:41
04.03.2021 08:01:41