EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety
device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian
opening
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and
R-AUX relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too long
Alarm from edge
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
Alarm from Self-learning failed
ACCESSORIES -
For the connections and the technical data of the optional equipments follow the relevant handbooks.
PLATE TO BE CEMENTED
PROBE
The probe detects the motor temperature to operate the heating system under low
temperature conditions, up to -30°C (connect to connector J8).
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
Off
Off
Off
10 seconds tone with 2 seconds pause
BUZZER STATUS
Off
Off
Off
Off
1 Tone
1 Tone
Off
Off
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
Off
1 Tone
2 Tones
Off
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
Off
6 Tones every 5 seconds
(It is renewed by giving a command)
Off
Continuous tone for 10 seconds with
2-second pause.
Not active when DIP 2 in OFF
code ACG8103
code ACG4665
36
FLASHER STATUS
Off
Flashes on-off 250 ms
Off
Flashes on-off 500 ms
Off
Flashes on-off 500 ms
Off
On steady
FLASHER STATUS
Off
Flashes intermittently red/green
Off
Flashes red for 10 seconds
Off
Flashes green for 10 seconds
Off
Flashes orange for 10 seconds
Off
Turns green once
Off
Turns red once
Off
Turns red once
Off
Runs 6 green flashes
Off
Runs 2 green flashes
FLASHER STATUS
Off
Led DL6 turns off
Off
Led DL7-8 turns off
Off
Led DL9-10 turns off
Off
Led DL1 flashes on-off 250 ms
Enabled for 1 minute
No led combined
Off
No led combined
Off
Led DL12 is steady on green.
Off
No leds matched
Off
Blue led flashes once every 5 seconds
Off
No leds matched
RACK MODULE 4
with zinc plated angle Iron, in 2 m bars.
DL1 LED STATUS
DL12 LED STATUS
LED STATUS AND SIGNAL OUTPUT
code ACS9050