InnoCigs REULEAUX RX GEN3 Mode D'emploi page 60

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

STEAMAX RX GEN3 – OPERATING AND SWITCHING OPERATING MODES
Changing the Wattage in TC/TCR Mode
Press the left or right Setting button when the symbol for wattage blinks and increase or reduce it this way. Press the Fire button to
confirm your setting.
Locking and Unlocking the Atomizer Resistor in TC/TCR mode
You can lock or unlock the resistance by pressing the right Setting button.
Note
1. Please use this lock function only at room temperature so that the correct base resistance can be displayed in lock mode. If this is not
the case, faulty measuring results can occur which can also adversely affect the protective functions.
2. A new head is identified in TC mode (temperature control). The confirmation inquiry "NEW COIL RIGHT, SAME COIL LEFT" will appear on
the display. Press the right Setting button if you are using a new head, or the left Setting button if you would like to continue vaping
with the previously used head.
3. If you inadvertently attempt to use conventional coils that are not suitable for temperature-controlled vaping or whose resistance is
greater than 1.5 ohms in TC or TCR mode, the device will automatically switch to VW mode.