Luminance Brands kathy ireland HOME GEODE Mode D'emploi page 23

Ventilateur de plafond de 52 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. Wall Control Installation
3-WAY INSTALLATION
(One Fan Controlled by Two Different Wall Controls)
(See Figures 35 and 36).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
8.4
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to install
the Ceiling Fan Wall Control into the Wall Box .
At All Wall Box locations remove Faceplates and
Screws from Existing Controls . Pull Controls out from
Wall Boxes and determine which Wall Box contains the
"HOT" Wire and which Wall Box contains the "LOAD"
Wire . Also, identify Traveler Wires which are common
to both Wall Boxes . Disconnect Wires from Existing
Controls only .
NOTE: Do not attempt to disconnect any Wires not
already connected to Existing Controls.
NOTE: Make all wiring connections using
wire connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
Before installing the First Wall Control, place the Wall
Control in "OFF" mode by pushing "ON/OFF" Switch
) to the "OFF" ( O ) position .
(
(Continued)
FAN/LIGHT
WALL
BLK
HOT
CONTROL
....
GND
OFF
ON
TRAVELER
WIRE
NEUTRAL
RECEIVER LOCATED
WITHIN THE CEILING
COVER
Figure 35
Install the First Wall Control in the Wall Box containing
the "HOT" Wire .
Connect the First Wall Control Black Wire labeled
"TO POWER SUPPLY" to the "HOT" 120V AC Supply
Source Wire . Securely connect the Wires with Wire
Connector, supplied (Figure 35) .
Connect the First Wall Control Black Wire labeled
"TO FAN" to both Traveler Wire(s) in the Wall Box and
secure with Wire Connector, supplied (Figure 35) .
Connect the First Wall Control Green Ground Wire
to the Supply Ground Conductor (this may be
a bare wire or wire with Green Colored insulation) .
Securely connect Wires with Wire Connector, supplied
(Figure 35) .
!
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
23
SECOND WALL
CONTROL PURCHASED
....
SEPARATELY
GND
OFF
ON
LOAD
BLACK
GROUND
WARNING
luminancebrands.com
Please contact 1-800-777-4440 for further assistance
ETL Model No.: CF370

Publicité

Table des Matières
loading

Table des Matières