1. ARMING: 
To arm the system, press  remote control BUTTON 1. Operation will be confirmed by 1 flash of the turn indicators, 2 
Beeps (if enabled) and the on‐board LED will turn ON steady. From this moment on the immobilizer, if connected, 
will no longer allow to start the engine. 
If during the arming delay, the seat/topcase input detects an anomaly (ex. seat open), it will be signaled by 1 flash of 
the turn indicators and 1 Bop after the arming confirmation tones. 
 
2. ARMING DELAY: 
After the arming confirmation tones, the LED turns ON steady to signal the arming delay countdown. Alarm events 
which might occur during the 20 sec. countdown will be ignored. 
 
3. TILT SENSOR EXCLUSION: 
To switch off the sensor, press BUTTON 4 within the first 4 sec. of the arming delay countdown. The LED will quickly 
turn  OFF  then  switch  back  ON  steady  to  confirm  successful  exclusion.  Sensor  operation  will  be  restored  upon  re‐
arming the alarm.  
 
4. SIREN EXCLUSION: 
During the first 4 sec. of the arming delay, the siren can be excluded by pressing remote control BUTTON 2. A quick flash of 
the turn indicators will confirm exclusion. The siren sound will be restored upon re‐arming the alarm. 
 
5. SYSTEM ARMED: 
The system will be fully armed after the arming delay countdown. The LED will flash to confirm the armed state. 
 
6. ALARM EVENTS: 
If  an  alarm  event  is  detected  during  the  armed  state,  the  siren  (if  not  previously  excluded  during  the  arming 
countdown), will sound and the turn indicators will flash repeatedly (0,5" ON – 0,5" OFF) for up to 25 sec. 
ALARM EVENT 
Ignition attempt 
Tilt sensor 
Wire tampering 
Seat/topcase input 
Alarm cycles can be interrupted, without disarming the system, by pressing remote control BUTTON 2.  
 
7. SYSTEM DISARMING WITHOUT ALARM MEMORY: 
If no alarm event has been detected, press remote control BUTTON 1 to disarm the system. Operation will be 
confirmed by 3 Beeps and 3 flashes of the turn indicators. The engine can then be started. 
 
 
8. SYSTEM DISARMING WITH ALARM MEMORY: 
If  an  alarm  event  occurs  while  the  alarm  is  armed,  disarming  will  be  confirmed  by  1  Bop  and  1  flash  of  the  turn 
indicators followed by one of more flashes of the turn indicators and Beeps according to the last alarm event: 
 2 Beeps and 2 flashes of the turn indicators => ignition attempt 
 3 Beeps and 2 flashes of the turn indicators => seat/topcase input 
 4 Beeps and 2 flashes of the turn indicators => wire tampering 
 5 Beeps and 2 flashes of the turn indicators => tilt sensor 
N.B.: If the acoustic signals have been disabled, only the turn indicators will flash as indicated above. 
 
 
 
 
BASIC FUNCTIONS 
ALARM DURATION 
25 sec. 
25 sec. 
25 sec. 
25 sec. 
ALARM CYCLES 
Unlimited 
7 alarm cycles 
Unlimited 
7 alarm cycles 