Ferroli EGEA 200 LT Manuel D'utilisation, Installation Et Entretien page 119

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EGEA
200 LT - 260 LT - 200 LT-S - 260 LT-S
Parameter Description
Temperature threshold for solar drain valve
/ solar collector roll-up shutter action in solar
P20
mode integration = 2 (direct control of thermal
solar system solar)
Lower water probe temperature value to stop
P21
the heat-pump in photovoltaic mode integration
Upper water probe temperature value to stop
P22
the electrical heater in photovoltaic mode
integration
P23
Photovoltaic mode integration
P24
Off-peak working mode
P25
Offset value on upper water temp probe
P26
Offset value on lower water temp probe
P27
Offset value on air-inlet temp probe
P28
Offset value on defrosting temp probe
P29
Antilegionella starting hour
Hysteresis on upper water probe for electrical
P30
heater working
Heat-pump working period in AUTO mode for
P31
heating rate calculation
Temperature threshold for electrical heater
P32
usage in AUTO mode
P33
Electronic-expansion valve (EEV) control
Superheating calculation period for EEV
P34
automatic control mode
Superheating setpoint for EEV automatic
P35
control mode
Desuperheating setpoint for EEV automatic
P36
control mode
EEV step opening during defrosting mode
P37
(x10)
Minimum EEV step opening with automatic
P38
control mode (x10)
P39
EEV control mode
Initial EEV step opening with automatic control
P40
mode / EEV step opening with manual control
mode (x10)
P41
AKP1 temperature threshold for EEV KP1 gain -10÷10°C
P42
AKP2 temperature threshold for EEV KP2 gain -10÷10°C
P43
AKP3 temperature threshold for EEV KP3 gain -10÷10°C
P44
EEV KP1 gain
P45
EEV KP2 gain
P46
EEV KP3 gain
Maximum allowed inlet temperature for heat-
P47
pump working
Minimum allowed inlet temperature for heat-
P48
pump working
Range
100÷150°C
30÷70°C
30÷80°C
0 = permanently deactivated
1 = activated
0 = permanently deactivated
1 = activated with ECO
2 = activated with AUTO
-25÷25°C
-25÷25°C
-25÷25°C
-25÷25°C
0÷23 hours
2÷20°C
10÷80 min
0÷20°C
0 = permanently deactivated
1 = activated
20÷90s
-8÷15°C
60÷110°C
5÷50
3~45
0= automatic
1 = manual
5÷50
-10÷10
-10÷10
-10÷10
38÷43°C
-10÷10°C
cod. 3541T600 - Rev. 08 - 12/2021
Default
140°C
62°C
75°C
0
0
2°C
2°C
0°C
0°C
23 hours
7°C
30 min
4°C
1
30 s
4°C
88°C
15
9
0
25
-1
0
0
2
2
1
43°C
-7°C
EN
Notes
Modifiable (2)
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable
Modifiable
119