ENGLISH
[SET CONFIG > DEFAULTS] –
This is your emergency exit if you really messed up the settings: just return to PRO or AUTO preset.
Also 2 user settings can be saved/loaded.
Press the ▲/▼/◄/► buttons until the desired function is showing on the display.
Press the [ENTER] button: the values can be changed
Use ◄/► buttons to select one of these options:
[PRO Use]: optimized standard settings for professional control of the unit.
[AUTO Use]: optimized standard settings for easy automatic control of the unit.
[USER Def.]: you can adapt the PRO or AUTO settings and save the new parameters as your
personal USER-settings.
Press the [ENTER] button:
[PRO Use] or [AUTO Use] was selected: the display shows "LOAD"
Press the [ENTER] button and use ▲/▼ buttons to confirm YES / NO
Press the [ENTER] button to confirm.
[USER Def.] was selected: the display shows "LOAD"
Use ◄/► buttons to select LOAD / SAVE
Press the [ENTER] button and use ▲/▼ buttons to confirm YES / NO
Press the [ENTER] button to confirm.
[SAVE] was selected: the current settings of the setup menu are saved to memory.
[LOAD] was selected: the previously saved settings are loaded.
PARAMETER name
[IP Protocol]
[CHAN mode]
[Install POS]
[NO DMX mode]
[LED behaviour]
[White Bal.]
[DIM Curve]
[FLOW invert]
[MATRIX Rot.]
[MIC Sense]
[Chase Repeat]
[PAN invert]
[TILT invert]
[PAN Range]
[FEEDBACK]
[FUNC. Delay]
[STANDBY]
[HEAD Fan]
[BASE Fan]
[Backlight]
[AUTO LOCK] Menu
[no DMX blink] display
[Temp C/F]
[SET CONFIG > TIMERS] –
Shows the time the projector was used.
Press the ▲/▼/◄/► buttons until the desired function is showing on the display.
Press the [ENTER] button: the values can be changed
Use ◄/► buttons to select one of these options:
[Total Time]: The total time the unit was used since it was used for the 1
[Last JOB]: The time the unit was used on the last job. This timer can be reset in the (hidden)
calibration menu.
Press the [ENTER] button to confirm.
BRITEQ
®
PRO defaults
AUTO defaults
Artnet
116 ch
Floor 180°
Floor 180°
Freeze
Halogen
NO factory default
NO factory default
Square
OFF
standard
85%
3
OFF
OFF
540
ON
3 sec
15 M
AUTO
AUTO
2 min.
OFF
ON
Celcius
11/107
OPERATION MANUAL
USER defaults
Artnet
Current setting in the menu
18 ch
Current setting in the menu
Current setting in the menu
Audio
Current setting in the menu
Halogen
Current setting in the menu
Current white balance is saved
Square
Current setting in the menu
OFF
Current setting in the menu
standard
Current setting in the menu
85%
Current setting in the menu
3
Current setting in the menu
OFF
Current setting in the menu
OFF
Current setting in the menu
540
Current setting in the menu
ON
Current setting in the menu
3 sec
Current setting in the menu
OFF
Current setting in the menu
AUTO
Current setting in the menu
AUTO
Current setting in the menu
ON
Current setting in the menu
OFF
Current setting in the menu
OFF
Current setting in the menu
Celcius
Current setting in the menu
st
time, non resettable.
BEAM WIZARD5x5-RGBW