c.
In this cases, remove the label with former nozzle indications from the burner.
Boiler
PU 153 Condens
–
GTU C 123
PU 154 Condens
Chimney
–
version
GTU C 124
PU 155 Condens
–
GTU C 125
Boiler
PU 153 Condens F –
Forced
GTU C 123 FF
flue
PU 154 Condens F
version
–
GTU C 124 FF
PU 155 Condens F
–
GTU C 125 FF
Boilers
Burner
DELAVAN 80°A
(chimney &
output
forced flue)
(kW)
USG
PU 153
Condens
(F) –
20
0.5
GTU C 123
(FF)
PU 154
Condens
(F) –
25
0.6
GTU C 124
(FF)
PU 155
Condens
(F) –
32
0.75
GTU C 125
(FF)
Injection nozzle
•
GTU C 123 – GTU C 124 - PU 153 Condens – PU 154 Condens
In order to allow for any problems on site, Delavan 80°A injection
nozzles can be replaced by Danfoss 80°S injection nozzles
•
PU 155 Condens (F) – GTU C 125 (FF) boilers (see table below)
We recommend at inspection or when the system is being handed
to replace the nozzle by a Fluidics 60°SF nozzle.
Since November 2005
As of burner serial no.:15047608
Up to burner serial no.: 17007484
0.5 USG – Delavan 80°A
0.6 USG – Delavan 80°A
0.75 USG – Delavan 80°A
Since November 2006
As of burner serial no.:16040245
Up to burner serial no.: 17007521
0.5 USG – Danfoss 80°S
0.55 USG – Danfoss 80°S
0.65 USG – Danfoss 80°S
Injection nozzle and oil pressure
DANFOSS 80°S
Oil
Oil
pressure
USG
pressure
(bar)
(bar)
11.5
0.5
11
11
0.55
11
12
0.65
10.5
Settings with corresponding nozzle since February 2007
SETTINGS TABLE:
FLUIDICS 60° SF
Number of
Oil
rings
USG
pressure
(bar)
-
-
2 x 1 mm
-
-
2 x 1 mm
0.65
12.5
4 x 1 mm
4
Since February 2007
As of burner serial no.:17008520
0.5 USG – Danfoss 80°S
N° SPC : 300011971
0.55 USG – Danfoss 80°S
N° SPC : 300011972
0.65 USG – Fluidics 60°SF
N° SPC : 300012423
Since February 2007
As of burner serial no.: 17008520
No change
No change
0.65 USG – Fluidics 60°SF
N° SPC : 300012423
Size
Indicative
injection
Recirculation
setting
nozzle /
slit (mm)
of the
baffle
air flap
2.5
4
50
2.5
2
75
2.5
5
120
Head
O
CO
2
2
pressure
(%)
(%)
(mbar)
7.5
4
12.5
8.5
4
12.5
8.2
4
12.5