CONNECTION
• Respect the direction of the water flow (see arrow engraved on the solenoid valve(s)).
• Install the filters supplied to protect the solenoid valve(s) from foreign bodies.
• Connect the solenoid valve(s) to the terminal EV (Fig. D) via the rubber compression gland:
- RED wire(s): EV+ terminal
- BLUE wire(s): EV- terminal
• Connect the sensor cable to the BMR terminal (Fig. D) via the rubber compression gland:
- WHITE wire: terminal B
- BROWN wire: terminal M
- RED wire: terminal R
• Do not cut or lengthen the sensor cable (standard 500cm length available on request).
• Tighten the nuts on the compression glands.
• Mount the wall unit under the washbasin at least 50cm above the floor with the compression glands
facing downwards.
• Replace the fixing screws, cover and seal, then close the box.
ADJUSTMENTS
Electronic unit:
• The detection distance can be adjusted using the potentiometer "GAIN" 11 (Fig. F)
located on the electronic unit.
• The comfort shut-off delay can be adjusted up to 12 seconds using the potentiometer "TEMPO" 7 (Fig. F)
located on the electronic unit.
• We do not recommend using the minimum or maximum positions.
• The duty flush 8 (Fig. F), is programmed to flush automatically for 60 seconds every 24 hours
after the last use. This can be cancelled or programmed to flush 12 hours after the last use by placing
the connecting pins in line with the desired programme (Fig. G).
5: 2 x 3Vcc batteries (type CR123A)
6: Operating "Mode" selector: leave in original setting
7: Adjusts the shut-off delay
8: "Duty flush" pin connector
9: Short range (PC) and Long range (PL) pin connectors (see also Fig. H)
10: Flashing LED (indicates if batteries need replacing)
11: Adjusts the detection distance
12: Screw terminal
Adjusting the flow rate (Fig. I) (except 20464 models):
• The flow rate is pre-set at the factory at 3 lpm (at 3 bar).
• The flow rate can be adjusted directly on the flow straightener using a 2.5 mm Allen key:
- notch 1 = 3 lpm (at 3 bar)
- notch 2 = 4 lpm (at 3 bar)
- notch 3 = 5 lpm (at 3 bar)