MAINTENANCE
If the mixer/tap does not flow when turned on:
Remove the batteries and replace them again.
If the mixer/tap does not flow and the LED on the sensor is flashing:
The battery power is too low for the solenoid valve(s) to operate, causing the LED on the sensor to flash
for 12 days. Change the batteries.
If water flows continuously with the solenoid valve(s) in the closed position:
• Unplug the solenoid valve cable(s) from the EV terminal.
• Connect the solenoid valve cable(s) directly onto the battery terminals 28 (Fig. O):
- Connect the red wire(s) 27 to the - terminal then the blue wire(s) 26 to the + terminal:
the solenoid valve(s) will open.
- Next, connect the red wire(s) 27 to the + terminal, and the blue wire(s) 26 to the - terminal:
the solenoid valve(s) will close (Fig. O).
• Connect the solenoid valve(s) to the EV terminal in the electronic unit (Fig. D):
- RED wire(s): EV+ terminal
- BLUE wire(s): EV- terminal
• Mixer: regularly check (as often as necessary) the temperature selector and the mixer's two internal
seats on which the side temperature selector turns. Replace as necessary.
• The non-return valves should be checked at least once a year.
• Beware: do not grease the inside of the mechanism.
MAINTENANCE & CLEANING
• Cleaning chrome: Do not use abrasive, chlorine or acid-based cleaning products.
Clean with mild soapy water using a cloth or a sponge.
• Frost protection: Drain the pipes and operate the mixer/tap several times to drain any remaining water.