Atag WG3X Mode D'emploi Et Instructions D'installation page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
assembly
(continued)
building-in dimensions island hood
800-1025
130
520
700
min. 650
fitting island models
The most important dimensions are given above. You can
adjust the height of the telescopic pipe. Bear in mind the
permitted tolerances.
It is advisable to suspend the hood with the help of an
assembly lift. If there is no lift present, it is advisable to carry
out the mounting with more than one person.
Position the discharge and the electrical connection in such
a way that it will be easy to hook up the hood.
marking
Mark the holes to be drilled on the ceiling by means of the
stencil.
Drill the holes (4 x 10 mm).
GB 14
¿150/125
250
240
755
1000
EG3/4/8X
assembly
(continued)
fitting the upper telescopic pipe
Fix the plugs and threaded ends in the ceiling. Screw two
nuts onto the threaded ends in the opposite direction. Screw
the threaded ends into the plugs in the ceiling, leaving
20 mm projecting.
20
Remove the nuts.
Place the upper telescopic pipe over the threaded ends. Put
the washers on and tighten the nuts.
mounting socket
Slide the mounting socket into the upper pipe until the
bottom edge is at the correct distance from the worktop (see
A
illustration).
650
Dimension A = 340 mm
Fasten the mounting socket using the four bolts (M5 x 12),
washers and nuts M5.
GB 15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wg4xWg8xEg3x maxusEg4x maxusEg8x maxus

Table des Matières