11 Supplement
Version
Hygienic
Vibration resistance
Shock resistance
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable gland
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Ʋ Size of digits
Adjustment elements
Protection rating
Ʋ unassembled
Ʋ mounted in the housing without lid
Materials
Ʋ Housing
Ʋ Inspection window
Integrated clock
Date format
Time format
Time zone Ex factory
Rate deviation max.
Measurement electronics temerature
Resolution
Accuracy
Permissible temperature range
58
Process fitting
SMS
Tuchenhagen Varivent
Clamp 3", 3½", 4"
further hygienic fittings
4 g at 5 ... 200 Hz according to EN 60068-2-6 (vibration
with resonance)
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
M20 x 1.5 or ½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Display with backlight
5
W x H = 7 x 13 mm
4 keys
IP 20
IP 40
ABS
Polyester foil
Day.Month.Year
12 h/24 h
CET
10.5 min/year
0.1 °C (1.8 °F)
±1 °C (1.8 °F)
-40 ... +85 °C (-40 ... +185 °F)
LEVEL TRANSMITTER 8138 • 4 ... 20 mA/HART - two-wire
Vessel pressure
-1 ... 6 bar (-100 ... 600 kPa/-14.5 ... 87 psig)
-1 ... 10 bar (-100 ... 1000 kPa/-14.5 ... 145 psig)
-1 ... 16 bar (-100 ... 1600 kPa/-14.5 ... 232 psig)