Electrical
connections
with the relevant VDE and DIN regula-
tions. Only use connecting cables with
H07RN-F mark.
An imprint of the type designation on the
power cable is mandatory.
AC motor
• The mains voltage must be 230 V~ /
50 Hz
• Extension cables up to 25 m length
must have a cross section of 1.5 mm
Power supply and extension cord must be
3-wire = P + N + SL. - (1/N/PE).
The mains supply is secured up to 16 A.
• The product meets the requirements of
EN 61000-3-11 and is subject to special
connection conditions. This means that
use of the product at any freely selecta-
ble connection point is not allowed.
• Given unfavorable conditions in the
power supply the product can cause the
voltage to fluctuate temporarily.
• The product is intended solely for use at
connection points that
a)do not exceed a maximum permitted
supply impedance "Z" (Zmax. = 0,418
Ω), or
b) have a continuous current-carrying
capacity of the mains of at least 100 A
per phase.
• As the user, you are required to ensure,
in consultation with your electric power
company if necessary, that the connec-
tion point at which you wish to operate
the product meets one of the two re-
quirements, a) or b), named above.
must
comply
.
2
www.scheppach.com
Connections and repairs of electrical
equipment may only be carried out by an
electrician.
Please provide the following information
in the event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
13. Maintenance
If personnel qualified for unusual mainte-
nance tasks or repairs must be obtained
during of after the warranty period, please
always contact a service point recom-
mended by us or contact the manufactur-
er.
• Only perform repair, maintenance and
cleaning work as well as the correction
of malfunctions with the drive switched
off as a basic rule.
• All protective and safety equipment
must be reassembled immediately after
repair, maintenance is completed.
Cleaning
m CAUTION! Disconnect the mains
plug.
• Clean the machine each time after com-
pleting work.
• The machine should be cleaned regu-
larly to remove dust and dirt.
• Keep safety devices, air vents and the
motor housing as dust and dirt-free as
possible.
• Clean the device with a clean cloth, or
blow it out with compressed air at low
pressure.
• All moving parts are to be re-greased at
periodic intervals.