• Do not reach into the machine while it
is running.
• Chips and splinters must not be re-
moved while the machine is running.
m WARNING! Danger of burns
The insertion tool may become hot during
use.
• when changing tools
• when setting the device down
m WARNING! This electric tool gen-
erates an electromagnetic field during
operation. This field can impair active or
passive medical implants under certain
conditions. In order to prevent the risk of
serious or deadly injuries, we recommend
that persons with medical implants con-
sult with their physician and the manufac-
turer of the medical implant prior to oper-
ating the electric tool.
Residual risks
Even when this electric tool is used
properly, residual risks still remain.
The following hazards may arise in
connection with the design and con-
struction of this electric tool:
• Lung damage if suitable dust protection
mask is not worn.
• Hearing damage if suitable hearing pro-
tection is not worn.
• Damage to health resulting from hand/
arm vibration if the device is used over
an extended period of time or if it is not
properly operated and maintained.
6. Technical Data
Dimensions
(L x B x H)
Stroke rate
Impact force
Weight
Motor
Rated input P1
Protection class
Protection category
Technical changes reserved!
Noise & vibration
m WARNING: Noise can have serious
effects on your health. If the machine
noise exceeds 85 dB (A), please wear
suitable hearing protection.
Noise data
Sound power level L
Sound pressure level L
Uncertainty K
Vibration parameters
Main Handle:
Vibration emissions value
a
h, Cheq
Uncertainty K = 1,5 m/s
Additional handle:
Vibration emissions value
a
h, Cheq
Uncertainty K = 1,5 m/s
www.scheppach.com
652 x 157 x 276
WA
pA
wa/pA
= 18,2 m/s
2
2
= 14,5 m/s
2
2
mm
2000 1/min
50 Joule
16 kg
230 V / 50 Hz
1600 W
B
IP20
105,0 dB(A)
84,0 dB(A)
2 dB(A)
GB | 43