17
Technical Information
Profibus
Profibus
General
The Profibus allows to communicate with the controller as Profibus
DP slave device.
The option works as a bi-directional bridge between the Profibus
network and the Agilent turbo controller internal link. The interface
provides input data (measures) and output data (commands) to the
controller, and in addiction provides standard and user related
diagnostics, in order to allow the user to manage the exceptions.
Insert only one module in the configuration of the TV 301-P Navigator Controller,
NOTE
even if it can accept up to four modules.
Mechanical
The Profibus interface is mounted on the bottom side of the
controller.
Figure 17
200/224
All manuals and user guides at all-guides.com
MAINS
FUSE TYPE
250V T 8A
LD1
STATUS
P3
P5
J6 SERIAL
VENT
FAN
ADDRESS
J2 PROFIBUS
MSD
LSD
STATUS
Profibus interface
TV 301-P Navigator Controller User Manual / 87-901-001-01 (B)
J5 IN-OUT
OPTION 1