Télécharger Imprimer la page

Agilent Technologies TV 301-P Navigator Notice De Mode D'emploi page 193

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
All manuals and user guides at all-guides.com
Using the RS 485 interface, the message structure re-mains identical to the one
NOTE
used for the RS 232 interface, the only difference being that the value assigned
to the ADDRESS <ADDR>
The controller can answers with the following response types:
Table 5
Type
Logic
Numeric
Alphanumeric
ACK
NACK
Unknown
Window
Data Type Error
Out of Range
Win Disabled
TV 301-P Navigator Controller User Manual / 87-901-001-01 (B)
RS 232/RS 485 Communication Description
Response types
Length
Value
1 byte
-
6 bytes
-
10 bytes
-
1 byte
(0x6)
1 byte
(0x15)
1 byte
(0x32)
1 byte
(0x33)
1 byte
0x34)
1 byte
(0x35)
Technical Information
Description
After a read instruction of a logic
window
After a read instruction of a numeric
window
After a read instruction of an
alphanumeric window
The command execu-tion has been
successfully completed
The command execu-tion has been
failed
The specified window in the
command is not a valid window
The data type specified in the
command (Logic, Numeric or
Alphanu-meric) is not accorded with
the specified Win-dow
The value expressed during a write
com-mand is out of the range value
of the specified window
The specified window is Read Only
or tempo-rarily disabled (for ex-
ample you can't write the Soft Start
when the Pump is running)
17
193/224

Publicité

loading