• Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting is zero. If the figure is negative, the impedance drops and the
arc becomes harder, while if it increases, the arc is softer.
To access this function, simply highlight it using the knob B and press it for less than 2 seconds. The display screen A
shows the adjustment bar. The figure can be changed and confirmed by pressing the knob B for less than 2 seconds.
.
• AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose is to adjust the length of the wire coming out of the gas nozzle
after welding. A positive figure corresponds to greater wire burning.
Default is Auto (preset function). To access this function, simply highlight it using the knob B and press it for less than
2 seconds. The display screen A shows the adjustment bar. The figure can be changed and confirmed by pressing
the knob B for less than 2 seconds.
• Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire speed expressed in percentage of the speed set for welding,
before the wire touches the piece to be welded.
This adjustment is important to always obtain good starts.
Default is Auto (preset function).
To access this function, simply highlight it using the knob B and press it for less than 2 seconds. The display screen A
shows the adjustment bar. The figure can be changed and confirmed by pressing the knob B for less than 2 seconds.