4
Calibration
1. Place the unit with its measuring edge (9) down on a straight surface
and mark the positions of the unit's ends on the underlying surface
(see Fig. below). Switch the unit on (1) and press the CAL button (4)
until -1- will appear in the display.
2. Then press the READ button (1). -1- flashes.
The display then changes to -2-.
3. Now turn the unit around horizontally (end-for-end) by 180°
such that its ends are positioned opposite where they previously
were but again exactly at the underlying surface marks (reverse
measurement). Then press the READ button (1) again. -2-
flashes. The subsequent acoustic signal concludes the process.
DigiLevel Compact
A quality product from
Donnerfeld 2, 59757 Arnsberg
Germany, Tel: +49 2932 638-300
Fax: -333, www.laserliner.com
!
The unit is properly calibrated when it displays the same
measurement value, i.e. the underlying surface's deviation
from absolute level, in both positions (0° and 180°).
5
HOLD
Hold down the HOLD button (6) to keep displaying the current
measured value.
6
Changing the angle reference value
With button (2), it is possible to transfer angles elsewhere.
To do so, set the device to the desired slope and press button (2).
The display then changes to „0.00°", „REF" appears on the display
and the required reference angle is set. The slope can now be
transferred to other objects.
Press button (2) again to deactivate the angle reference.