The operating mode of the PHOT input is selected.
On: PHOT input is activated in both opening and closing.
In the opening phase: when the contact is opened, the motor stops. When the photocell is released,
the motor restarts with an opening movement.
PHTo
In the closing phase: when the contact is opened, the motor stops. When the photocell is released, the
motor inverts its movement direction (opens).
Off: PHOT input is activated only in the closing phase.
In the closing phase: when the contact is opened, the motor stops and the movement direction is
immediately reversed (opens).
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE LEARNING).
rem
On: Enabled remote storage
Off: Disabled remote storage.
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-by-step function.
Press the transmitter key to be assigned to this function.
PP
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
With AUX:1 parameter, the radio channel II function to terminals 19/20 is activated.
With AUX:0 e AUX:2 parameter, the service light is activated according to the time preset by TLS parameter.
2Ch
By selecting this function, the receiver awaits (Push) the pressure of the key to be matched with that function.
If the code is valid, the same is memorised and the OK message is displayed.
If the code is not valid, the Err message is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
CLR
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
RTR
Completely erase the receiver memory. Confirmation of operation is required.
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>>
<PG> 3456: made 123.456 cycles.
12.5) MAINTENANCE CYCLES (MACI)
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of ma-
noeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or closing
operation.
The warning of maintenance required is indicated to the user through the flashing of the courtesy light LEDs during the opening and closing phases.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The
transmitters are not erased from the receiver nor is the access password.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The
transmitters are not erased from the receiver nor is the access password.
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password is typed in,
it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to allow adjustments and tests
on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other menu. If a
protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
26
12.3) RADIO (RAD)
12.4) CYCLES NUMBER (NMAN)
12.6) RESET (RES)
12.7) RESET (RES)
12.8) PROTECTION CODE (CODE)
FUNZIONE
(OFF)
(ON)