Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Psc
The torque applied to the motor during braking in the opening phase is adjusted *
The activation time of the service light is adjusted.
TLS
With parameter :0, the area light function is activated. The light is switched on when the motor is
moving and during the TCA dwell time. The light switches off when the motor stops.
The triggering threshold of the anti-crash device (Encoder) during the normal speed phase.*
SEAV
99: maximum sensitivity - 0: minimum sensitivity
The triggering threshold of the anti-crash device (Encoder) during braking.*
SEAR
99: maximum sensitivity - 0: minimum sensitivity
The operating mode of the auxiliary output to terminals 19/20 is preset. See wire connections in figure 20.
0: output configurated as SCA (open gate indicator light): Off with closed door, on with open
door, slow flash during opening, rapid flash during closing.
1: output configurated as radio channel II integrated receiver.
AUX
2: output configurated as PHOT TEST (photocell test).
3: output configurated as flashing light.
4: output configurated as service light additional to the light on the geared motor. Its activation
time is adjusted by TLS parameter.
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter have
IbL
no effect in the opening phase.
Off: disabled multi-flat function.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
PRE
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the motor.
Off: disabled forewarning flashing light.
The lock function in the closing phase is enabled or disabled.
blc
On: Lock function is enabled.
Off: Lock function is disabled.
During the TCA time, the blinker is enabled or disabled.
ltca
On: Activated blinker.
Off: De-activated blinker.
The pick-up function with ENC:OFF logics is activated or deactivated.
spn
On: the function is enabled. The first two seconds of operation are carried out at maximum torque.
With ENC:ON logics, pick-up is automatically adjusted by the control unit.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the PP/CLOSE push-buttons must be kept pressed.
Off: Automatic/semiautomatic operation.
PP input as OPEN are enabled or disabled.
OPCL
On: PP input is enabled as OPEN.
Off: PP are enabled with their function.
During the TCA phase, the PP and transmitters controls are enabled or disabled.
IBCA
On: PP and TX controls are disabled.
Off: PP and TX controls are enabled.
The Encoder is enabled or disabled.
On: Enabled encoder.
ENC
Off: Disabled encoder (to be used with ZED series motors that are not equipped with built-in Encoder).
NB: The Encoder can be possibly reset (from OFF to ON). A new self-calibration procedure is required
(AUTO menu).
* WARNING:
An incorrect setting of these parameters may cause danger.
Please comply with regulations in force!

12.2) LOGIC (LOG)

FUNCTION
30-99-(50%)
0-240-(60s)
0-99-(0%)
0-99-(0%)
EN
0-4-(0)
ON-OFF-
MEMO
(Default)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zedl.rie

Table des Matières