De-activating the lock
In both modes, to de-activate thelock, press and hold the key
"Econo"
until the message "LocP" or "LocF" disappears
and is replaced by the message "ULoc".
NOTES
- If their is a power outage, the keyboard lock (either partial
or total) is removed.
- If you want to change for partial lock to total lock (or vice-ver-
sa), you must first deactivate it and then set the new lock mode.
I
TEMPORARY SYSTEM SHUTDOWN
("STANDBY")
This function lets you suspend operation of all system devices for
a period of 60 minutes (this value cannot be changed) so that
you can perform routine maintenance without having to discon-
nect the power supply.
ATTENTION
If you need to access the electrical parts, parts which
are normally powered, or the rotating parts of the
pumps, you must turn off the omnipolar switch(es).
To activate the function, press and hold the "Filter"
about 5 seconds: the display will show the message "Sby" followed
by the number of minutes the function will remain active.
The function ends when the 60 seconds are up, or by press-
ing and holding the "Filter"
Any filtering cycles which had been suspended will resume op-
eration, as programmed.
NOTE: if filtering cycles are active at the end of the standby
condition, they will restart.
I
WINTER SHUTDOWN
In areas where winter temperatures frequently drop below 0° C,
during the period when the spa is not in use it is advisable to com-
pletely drain the system (spa, compensation tanks, pipes, filter).
In areas where temperatures only occasionally drop below 0
°C, the spa can be left in operation, since it is equipped with an
anti-freeze protection that ensures that a minimum water tem-
perature is maintained (see the chapter "Setting water tem-
perature", which contains paragraphs on maintaining the min-
imum water temperature and preventing freezing of water in the
pipes - "Smart Winter" mode).
key for
key for another five seconds.
I
MAINTENANCE
I
GENERAL INSTRUCTIONS
Keep the spa covered at all times when not in use. In this way,
along with keeping the water from getting dirty, you will also avoid
heat loss and evaporation.
ATTENTION
The cover is not designed to support weights. Do
not stand, sit or lie on the cover, and do not set ob-
jects on it.
To clean the suction nozzles, remove the cover and its o-
ring, thoroughly clean the parts and remove any residue.
NOTES
- the intakes must be cleaned with the tub empty. Remember
to refit all the parts before re-filling the spa.
-the suction intake grilles must be checked at least once a
week.
For long periods of disuse, it is advisable to completely drain
the system (refer to the chapter on emptying the tub and win-
ter shutdown). Periodic drainage, during normal use, vary de-
pending on the frequency of use, the contaminants and the type
of installation.
Even if not used particularly frequently, you should change the
water at least once a month.
32