Changing the Workpiece Protector (see figure G)
The workpiece protector 1 at the end of the discharge lock-
off 2 protects the workpiece until the power tool is correct-
ly placed for the driving procedure.
The workpiece protector can be removed and replaced.
– Pull the workpiece protector from the discharge lock-
off.
– Push the new workpiece protector via the open end
over the discharge lock-off.

Maintenance and Service

Maintenance and Cleaning

Block the actuation system and remove
the battery before making any adjust-
ments, changing accessories, or placing
the power tool aside. This safety measure
prevents accidental starting of the power
tool.

Maintenance Schedule

Clean the magazine 12. Remove any plastic or wood chips
that may accumulate in the magazine during operation.
Clean the power tool in regular intervals using compressed
air.
Measure
Cleaning the magazine 12 and magazine slider 13.
Ensuring that the discharge lock-off 2 functions properly.

Correction of Malfunctions

Problem
The machine is not operative.
The power tool is ready for operation, but no nails are dis-
charged.
1 619 929 K10 | (15.7.11)
Note: A spare workpiece protector can be stored at the top
side of magazine 12. For this, push the workpiece protec-
tor into the depot 10.
Transport and Storage
When transporting the power tool, block the actuation sys-
tem (see "Blocking the Actuation System", page 13), espe-
cially when using ladders or moving in an unusual stance or
posture.
For safe and proper working, always keep the ma-
chine and ventilation slots clean.
If the machine should fail despite the care taken in manu-
facturing and testing procedures, repair should be carried
out by an after-sales service centre for Bosch power tools.
Explanation
Prevents the jamming of nails.
Promotes your work safety and efficient use of the power
tool.
Cause
The battery is discharged or defective.
The battery is not properly inserted.
The battery temperature is too high or too low.
The battery contacts are contaminated/dirty or defec-
tive.
The actuation system is blocked.
The magazine 12 is empty.
The discharge lock-off 2 is bent.
The electronic system is defective.
The following components may be faulty:
– Trigger 6
– Driver blade
– Motor or drive belt
– Electronic system
Foreign objects have accumulated in the shot mecha-
nism.
Foreign objects have accumulated in the outlet 15 or in
the magazine 12.
A nail is jammed in the shot duct.
The magazine slider is 13 defective.
The spring of the magazine slider is too week or defec-
tive.
The fasteners being used are not permitted.
The magazine 12 is empty.
At the workplace, carry the power tool only by the handle 9
and with the trigger released 6.
Always store the power tool disconnected from the battery
and at a dry and warm location.
When not using the power tool for a longer period of time,
apply a fine oil coating to steel parts. This prevents the for-
mation of rust.
In all correspondence and spare parts order, please always
include the 10-digit article number given on the type plate
of the machine.
Action
– Blow out the mechanism of the magazine/magazine slider
daily with compressed air.
– Blow out the mechanism of the discharge lock-off daily with
compressed air.
Corrective Measure
– Fully recharge the battery or exchange it.
– Make sure that the battery has engaged properly in the
handle.
– Wait until battery has reached the optimal operating tem-
perature again.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Press switch 5 toward the right to disengage the actuation
system.
– Refill the magazine.
(See "Loading the Magazine", page 13)
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Contact an authorised service agent for Bosch power tools.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Clean the outlet 15 or the magazine 12.
– Clear the jam.
(See "Clearing Jams", page 13)
– Clean the magazine slider 13 as required and make sure
that the magazine 12 is not dirty/soiled.
– Contact an authorised service agent for Bosch power tools.
Have the component replaced there.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified in table
"Technical Data" may be used.
– Refill the magazine.