DIsConneCtInG Hoses
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Push coupler on quick connect body back to release quick
connect plug on hose.
230 Volt Conversion
To operate the compressor at 230 volts replace the
115 volt plug supplied on the motor cord with a
UL/ CSA listed plug suitable for 230 volts and the
rated amps of the compressor, see Motor
Specifications at the beginning of this manual. A 230
volt plug as shown in the diagram may be purchased
at a local hardware or electrical supply store.
1. Follow the plug manu facturer installation
procedures, contact a qualified electrician, a D
center or call 1-800-4-D
WALT (1-800-433-9258) for assistance.
e
IMPortAnt: The compressor must comply with all local and
national electrical codes after the 230 volt plug is installed.
WARNING: Ensure the 230 volt cord plug end is properly
connected before operating in 230 volt mode.
2. Remove the pin on the 115/230 dual voltage
control switch.
3. Move the 115/230 dual voltage control
switch (N) to the 230 volt position.
4. Replace the pin.
CAUTION: Once the unit has been converted
to 230 volts the 115/230 dual control switch
can not be placed in the 115 volt position until
the cord plug is replaced with a UL/CSA listed cord plug suitable
for 115 volts and the rated amps of the compressor, See Motor
Specifications.
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.

Grounding Instructions

WARNING: Risk of electrical shock. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (P) with this unit
contains a grounding pin (Q). This plug
Must be used with a grounded
outlet (O).
WALT service
e
IMPortAnt: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the
same configuration as the grounded
plug. DO NOT USE AN ADAPTER.
N
3. Inspect the plug and cord before each
use. Do not use if there are signs of
damage.
4. If these grounding instructions are
not completely understood, or if in doubt as to whether the
compressor is properly grounded, have the installation checked
by a qualified electrician.
DANGER: Risk of electrical shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
11
115V
P
O
Q
230V
O
P
Q