OIL DIPSTICK
The oil dipstick (K) indicates the amount
of oil in the pump. Check pump oil
daily,
see
Compressor
under Maintenance.
AIR INTAKE FILTER
The filter (M) is designed to clean air entering
the pump. To ensure the pump continually
receives a clean, cool, and dry air supply
the filter must always be clean and the filter
intake must be free from obstructions.
INSTALLATION
Assembly
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Grasp the hose at the quick connect plug and
push the plug into the quick connect body (E).
Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler
is seated.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 PSI (0 kPa).
2. Pull coupler on quick connect body back to release quick connect
plug on hose.
K
Pump
Oil
Lubrication and Oi
M
CAUTION: The compressor was shipped with oil in the crankcase.
A shipping plug is used to prevent oil from leaking during shipment.
Do not attempt to operate this air compressor without first checking
the oil level. Serious damage can result from even limited operation
unless filled with oil and broken in correctly. Closely
follow Initial Set-up under Operation.
CAUTION: Use SAE 5W-40 full synthetic oil.
1. Place unit on a level surface.
2. Remove
the
shipping
the dipstick.
3. Remove the dipstick (K) and check the oil level.
Oil should not exceed top raised line on dipstick.
If oil is below lower mark see Checking Oil under Compressor
Pump Oil under MAINTENANCE. NOTE: See Specifications for
pump oil capacity.
CAUTION: Risk of unsafe operation. Overfilling with oil will cause
premature compressor failure. Do not overfill.
4. Replace dipstick.

Grounding Instructions

E
WARNING: Risk of electrical shock. In the event of a short circuit,
grounding reduces the risk of shock by providing an escape wire for
the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (O) with this
unit contains a grounding pin (P). This
plug MUST be used with a grounded
outlet (Q).
10
K
plug
and
install
O
Q
P