possible to check the state of charge when the power tool is
not in operation.
Press the button for the battery charge indicator or
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
The state of charge of the battery is also displayed on the
user interface (see "Status indications", page 33).
Battery model GBA 18V...
LED
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
Battery model ProCORE18V...
LED
5 × continuous green light
4 × continuous green light
3 × continuous green light
2 × continuous green light
1 × continuous green light
1 × flashing green light
Recommendations for Optimal Handling of the
Battery
Protect the battery against moisture and water.
Only store the battery within a temperature range of −20 to
50 °C. Do not leave the battery in your car in the summer, for
example.
Occasionally clean the ventilation slots on the battery using a
soft brush that is clean and dry.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
Follow the instructions on correct disposal.
Fitting
®
Using the Bluetooth
Low Energy Module
®
Note: The Bluetooth
Low Energy Module GCY 42 is avail-
able as an accessory for power tools GWX 18V-10 PC; the
®
Bluetooth
Low Energy Module GCY 42 is included in the
scope of delivery of power tools GWX 18V-10 SC / GWX
18V-10 PSC.
Bosch Power Tools
Read the corresponding operating instructions for informa-
tion about the Bluetooth
to
Fitting Protective Equipment
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Note: If the grinding disc breaks during operation or the
holding fixtures on the protective guard/power tool become
damaged, the power tool must be sent to the after-sales ser-
vice immediately; see the "After-Sales Service and Applica-
tion Service" section for addresses.
Capacity
Protective guard for grinding
60–100 %
30–60 %
5–30 %
0–5 %
Capacity
80–100 %
60–80 %
40–60 %
Adjust the position of the protective guard (14) to meet the
20–40 %
requirements of the operation. To do this, push the unlock-
5–20 %
ing lever (1) upward and rotate the protective guard (14)
into the required position.
0–5 %
Always position the protective guard (14) such that
u
the two cams on the unlocking lever (1) engage in the
corresponding openings on the protective guard (14).
Adjust the protective guard (14) such that sparking in
u
the direction of the operator is prevented.
The protective guard (14) must only be adjustable
u
while the unlocking lever (1) is actuated. Otherwise,
the power tool must not be used any more under any
circumstances and must be sent to the after-sales ser-
vice.
Note: The coding cams on the protective guard (14) ensure
that only a protective guard that is suitable for the power
tool can be fitted.
Protective guard for cutting
For cutting, always use the protective guard for
u
cutting (15) or the protective guard for grinding (14)
together with the cover for cutting (18).
Provide sufficient dust extraction when cutting stone.
u
The protective guard for cutting (15) is fitted in the same
way as the protective guard for grinding (14).
English | 29
®
Low Energy Module GCY 42.
Place the protective guard
(14) onto the holder on the
power tool until the coding
cams of the protective guard
are aligned with the holder.
When doing so, press and
hold the unlocking lever (1).
Press the protective guard
(14) onto the spindle collar
until the shoulder of the pro-
tective guard is sitting on the
flange of the power tool and
rotate the protective guard
until it audibly clicks into
place.
1 609 92A 766 | (17.02.2022)