4. TECHNICAL SPECIFICATIONS
4.1 General specifications
Environment conditions:
1000V CAT II and 600V CAT III
Pollution degree: 2
IP rating: 20
Altitude: <2000 m
Operating temperature:
0~40 ºC / 32~122 ºF (<80% RH, <10 ºC non-condensing)
Storage temperature:
-10~60 ºC /14~140 ºF (<70% RH, battery removed)
Temperature coefficient:
0.1 x (specified accuracy) / ºC (<18 ºC or >28 ºC)
Max. voltage between terminals and ground:
1000V AC RMS or 1000V DC
Figure 3-10 - NCV
Sample rate:
3 Hz for digital data
Display:
3-3/4 digit LCD display with automatic indication of functions and symbols
Range selection:
automatic or manual
Overrange indication:
LCD displays " "
Low battery indication:
displayed when the battery is below the normal range
Polarity indication:
"–" displayed automatically
Power source: 4.5V
Battery type: 3x AAA
4.2 Measurement specifications
Accuracy is specified for one year after calibration, in the operating temperature
range 18 ºC to 28 ºC with relative humidity less than 80%.
Accuracy specifications take the form of: ±(% of reading + number of least
significant digits).
4.2.1 Voltage
DCV:
Range
Resolution
400mV
0.1mV
4V
1mV
40V
10mV
400V
100mV
1000V
1V
Accuracy
±(0.5% of rdg + 5 digits)
±(0.8% of rdg + 5 digits)
±(1.0% of rdg + 2 digits)
12