The FireHawk M7 HUD, located on the Ultra Elite® Facepiece allows a
user to see cylinder pressure in one quarter cylinder increments, PASS
pre-alarms, battery status, and telemetry information (optional) while
wearing the air mask.
The FireHawk M7 HUD is compatible with the Fire Hawk M7XT Air Mask,
FireHawk M7 Air Mask, the FireHawk Air Mask withNightFighter
Heads-Up Display System, and the ICM® Tx/TxR.
Approved* HUD Transmitter
FireHawk M7XT Control Module
FireHawk M7 Control Module
NightFighter HUD Transmitter
ICM Tx Transmitter
*Model numbers are located on the back of the HUD Transmitters.
NOTE: To ensure compatibility, the ICM manufacturing date recorded
inside the battery compartment must be June 2006 or newer. For older
dates, contact MSA Customer Service at 1-877-672-3473.
NOTE: This quick reference guide provides user instructions for the
FireHawk M7 HUD (Heads-Up Display) receivers that are marked
"Interchangeable" and labeled with revision code B0-XX-XX or higher
(located next to the approval label). Refer to the appropriate user
manual for instructions pertaining to FireHawk M7 HUD use, most of
which are on the SCBA Instruction Manual CD, P/N 10128283.
User Instructions
FireHawk M7XT Air Mask
FireHawk M7 Air Mask
FireHawk Air Mask
NightFighter HUD Transmitter
ICM Tx Transmitter
ICM TxR Transmitter
MSA 715 (L) Rev. 10
M7 HUD
®
7-2719-1
7-2183-1
7-1215-1
7-1219-1
7-1861-1
7-1215-1
7-1219-1
7-1861-1
10128861
10082858
10023838
10035580
10058881
10068930
© MSA 2017
FIREHAWK M7 HUD FUNCTIONALITY
1. The HUD allows the user to see the cylinder pressure while wearing
the air mask. The transmitter wirelessly transmits a signal to the
HUD (on the facepiece) while the air mask is in use. The HUD
displays the cylinder pressure in regular cylinder increments, by an
LED pattern.
• As each cylinder pressure increment is reached, a unique LED
pattern will be displayed for approximately 20 second before
extinguishing. Refresh the display by pressing the mode
button on the transmitter (green on the FireHawk M7XT / M7
Control Module and ICM Tx/TxR or the only button on the
NightFighter approximately three seconds).
• When the End-of-Service-Time Indicator (EOSTI) service
pressure is reached (33% for FireHawk M7XT, 25% for all other
models), a single flashing red LED will be displayed and will
continue to flash until the unit is turned off or the cylinder is
refilled.
• The HUD must be within approximately 18 inches of the HUD
Transmitter to properly receive the signal being transmitted.
2. The HUD has a buddy light that also flashes red when the air mask
reaches the EOSTI service pressure. This buddy light is not visible to
the user while the air mask is in use.
3. When the user of the air mask remains motionless for
approximately 20 seconds, the PASS pre-alarm (if an integrated
PASS is in use) will begin to sound. During this pre-alarm, the HUD
will display an orange LED, and this LED will extinguish when full
PASS alarm is reached or the pre-alarm is reset.
4. When an evacuation command is sent to the user (if an optional
telemetry module is in use), the HUD will display an alternating red
and orange LED until the evacuation is confirmed.
5. The HUD has a photo sensor that automatically adjusts the
brightness of the LEDs based on the intensity of the ambient light
measured outside of the facepiece.
6. The HUD indicates a low battery condition for the HUD and / or
HUD Transmitter by a flashing yellow LED. The HUD transmitter
battery status is also indicated by a battery icon on the FireHawk
M7/M7XT Control Module/or ICM Tx/TxR HUD Transmitters. If a low
battery is indicated, return to fresh air, and replace the batteries
immediately.
Print Spec. 10000005196 (V)
Mat. 10106000
Doc. 10106000

Publicité

loading

Sommaire des Matières pour MSA FireHawk M7 HUD

  • Page 1 The transmitter wirelessly transmits a signal to the HUD (on the facepiece) while the air mask is in use. The HUD The FireHawk M7 HUD is compatible with the Fire Hawk M7XT Air Mask, displays the cylinder pressure in regular cylinder increments, by an FireHawk M7 Air Mask, the FireHawk Air Mask withNightFighter LED pattern.
  • Page 2 FIREHAWK M7 HUD QUICK REFERENCE GUIDE NOTE: Refer to the chart below for a full description of all HUD LED 6. Insert three AAA alkaline batteries in the appropriate locations on patterns. the cartridge. Follow the notations on the cartridge to ensure proper battery orientation.
  • Page 3 M7 HUD ® GUIDE DE RÉFÉRENCE RAPIDE Le FireHawk M7 HUD, placé sur le masque Ultra Elite®, permet à FONCTIONNEMENT DU FIREHAWK M7 HUD l’utilisateur de voir la pression de la bouteille par incréments de quart de bouteille, les pré-alarmes PASS, l’état de la pile et les informations de Le HUD permet à...
  • Page 4 GUIDE DE RÉFÉRENCE RAPIDE DU FIREHAWK M7 HUD REMARQUE: Consulter le tableau ci-dessous pour obtenir une AVERTISSEMENT description complète de tous les motifs de DEL du HUD. Utiliser seulement des piles alcalines Rayovac 824 LR03, Rayovac Ultrapro LR03, Energizer E92, Energizer Industrial EN92, Duracell REMPLACEMENT DES PILES MN2400 ou Duracell Procell PC2400 dans le HUD.
  • Page 5 2006. Si la fecha es anterior, comuníquese con el Servicio al cliente Si el usuario de la máscara de aire permanece quieto durante de MSA llamando al 1-877-672-3473. aproximadamente 20 segundos, comenzará a sonar la alarma previa de no movimiento PASS (si se usa PASS integrado). Durante NOTA: Esta guía de referencia rápida proporciona las instrucciones para...
  • Page 6 Parpadeará continuamente LED anaranjado para alarma previa de no movimiento PASS (PASS integrado) Indicador LED rojo/naranja para señal de evacuación Alternativamente rojo y naranja (módulo de telemetría) MSA 715 (L) Rev. 10 - 10106000...