BULK
NIGHT
ABSORPTION
CHARGE
Figure 4-1. EcoBoost MPPT Charging Algorithm
WARNING: Risk of Explosion
Equalizing vented batteries produces explosive gases.
The battery bank must be properly ventilated.
CAUTION: Equipment Damage
!
Equalization increases the battery voltage to levels that
may damage sensitive DC loads. Verify all system loads
are rated for the temperature compensated Equalize
voltage before beginning an Equalization charge.
CAUTION: Equipment Damage
!
Excessive overcharging and gasing too vigorously can
damage the battery plates and cause shedding of active
material from the plates. An equalization that is too
high or for too long can be damaging. Review the
requirements for the particular battery being used in
your system.
Battery Charge Settings
Preset EcoBoost MPPT battery charging options are shown
in tables 4-1 and 4-2 below. All voltage settings listed are
for nominal 12 Volt batteries. Multiply the voltage settings
by two (2) for 24 Volt batteries.
24
Operation
FLOAT
NIGHT
TIME
NOTE: These settings are general guidelines for
use at the operator's discretion. The EcoBoost MPPT
can be programmed to satisfy a wide range of charging
parameters. Consult the battery manufacturer for optimal
battery charge settings.
DIP
Absorp.
Float
Equalize
Switch
Battery
Stage
Stage
Stage
Settings
Type
(volts)
(volts)
(volts)
4-5-6
off-off-off 1 - Sealed*
14.00
13.50
off-off-on 2 - Sealed*
14.15
13.50
14.40
off-on-off 3 - Sealed*
14.30
13.50
14.60
off-on-on 4- AGM/Flooded
14.40
13.50
15.10
on-off-off 5 - Flooded
14.60
13.50
15.30
on-off-on 6 - Flooded
14.70
13.50
15.40
on-on-off 7 - L-16
15.40
13.40
16.00
on-on-on 8 - Custom
Custom
Custom
Custom
* "Sealed" battery type includes gel and AGM batteries
Table 4.1. Battery charging settings for each selectable battery type
Absorption Extension Voltage
Absorption Extension Time
Float Exit Time-out
Float Cancel Voltage
Equalize Time-out
Temperature Compensation Co-efficient
Table 4.2. Battery settings that are shared among all battery types
EcoBoost MPPT Operator's Manual
Equalize
Equalize
Absorp.
Equalize
Equalize
Equalize
Equalize
Equalize
Time
Time
Timeout
Interval
LVD
LVR
Interval
Interval
(volts)
(volts)
(mins)
(mins)
(mins)
(days)
(days)
(days)
150
11.50
12.60
150
60
120
28
11.30
12.80
150
60
120
28
11.50
13.00
180
120
180
28
13.20
11.70
180
120
180
28
11.90
13.40
180
180
240
28
12.10
13.60
180
180
240
14
12.30
13.80
Custom
Custom
Custom
Custom
Custom
Custom
Custom Custom
Custom
12.50
Volts
Absorption Time + 30
minutes
30
minutes
12.30
Volts
Equalize Time + 60
minutes
millivolts / °C
- 30
/ 12V
25