Specifications - Festo SPAW B2R Mode D'emploi

Capteur de pression
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Safety / 3. Specifications

3. Specifications

Specifications
EN
Model designation
Start of measuring range
End of measuring range
Overpressure safety
Display
Output signal
Zero offset adjustment
Analogue signal
Switching output
Power supply U
B
Current consumption
Total current consumption
8
OI_14070935_SPAW_GB_D_F_E.indd 8
SPAW
SPAW-...
B2R
B11R
P2R
bar
-1
-1
0
bar
1
10
2
bar
2
20
4
14-segment LED, red, 4-digit, 9 mm character size
Display can be turned electronically through 180°
Update (adjustable): 100 / 200 / 500 / 1,000 ms
without analogue signal
4 ... 20 mA
DC 0 ... 10 V
2 x Switching output PNP (option: NPN)
max. 3 % FS
current output load: ≤ 500 Ω
voltage output load: > 10 kΩ
settling time: 3 ms
Switch point 1 and 2 are individually adjustable
Normally-open and normally-closed function: freely adjustable
Window and hysteresis function: freely adjustable
Switching current: maximum 250 mA
Switching voltage: Power supply - 1 V
Settling time: ≤ 10 ms
DC 15 ... 35 V
The power supply for the pressure transmitter must be made via an energy-limited electrical
circuit in accordance with section 9.3 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC
60950-1, or class 2 in accordance with UL1310/UL1585 (NEC or CEC). The power supply
must be suitable for operation above 2,000 m should the pressure transmitter be used at
this altitude.
max. 100 mA
max. 600 mA including switching current
P6R
P10R
P16R
P25R
0
0
0
0
6
10
16
25
12
20
32
50
Pressure sensor SPAW
P50R
P100R
0
0
50
100
100
200
05.08.2013 11:02:26

Publicité

Table des Matières
loading

Table des Matières