3. OPERATION
The operating voltage of the unit is stated on the unit label.
The beacon can be powered directly only.
4
M5 Direct Fixing
Hole 2 Positions
All Dimensions in Milllimetres
4. MAINTENANCE
During the working life of the unit, it should require little or no maintenance. However, if abnormal or unusual
environmental conditions occur due to plant damage or accident etc., then visual inspection is recommended.
If a unit fault should occur, then the unit can be repaired by Cooper MEDC. All parts of the unit are replaceable.
If you acquired a significant quantity of units, then it is recommended that spares are also made available. Please
discuss your requirements with the Technical Sales Engineers at Cooper MEDC.
During maintenance, if the cover/lens assembly grease needs to be re-applied, a PFPE (Perfluoropolyether)
based grease such as Krytox GPL203 by DuPont or Perfluorolube 22/6 by Performance Fluids Ltd should be
used, to prevent damage to the O-ring.
5. CERTIFICATION/APPROVALS
IECEx units
Certified to IEC60079-0, IEC60079-1, IEC61241-1-1
IECEx certification No. IECEx BAS 05.0048X
For a 60W bulb:
E xd IIC T200°C (Tamb -55°C to +70°C)
T135°C (Tamb -55°C to +55°C)
For a 100W bulb:
E xd IIC T200°C (Tamb -55°C to +40°C)
07/15
GENERAL ARRANGEMENT
Ø8.5 Fixing Hole
2 Positions
Optional Backstrap
Certification Label
-
Duty/Tag Label
Optional Cast Guard
Optional Wire Guard
© MEDC 2015