Carrier 80HMA Mode D'emploi page 31

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 75
Variable table
Nr.
Name
Par.
Defines if Domestic hot water is
managed by:
1. System control (it needs
Sanitary Water Temperature
Sensor installed and mapped
Managing of
on Par112.0)
71
Sanitary Water
2. System control with Solar
production
(it needs Sanitary Water
Temperature Sensor installed
and mapped on Par112.0)
3. External control (it needs Dry
Contact Thermostat installed
and mapper as Input)
Sanitary Water
Temperature
Value of Sanitary Water
72
Priority 0
temperature for Priority 0 in the
(Point D in
Priority Chart (pic. 7S) (°C)
pic. 7S)
Delta Sanitary
Value of Delta from Par. 72 value
Water
of Sanitary Water temperature
73
Temperature
for Priority 0.5 in the Priority
Priority 0.5 (Ref.
Chart (fig. 7S) (°C)
E in pic. 7S)
Delta Sanitary
Value of Delta from Par73 value
Water
of Sanitary Water temperature
74
Temperature
for Priority 1 in the Priority
Priority 1(Ref.
Chart (fig. 7S) (°C)
F in pic. 7S)
Delta Room
Value of Delta from room
Setpoint
75
Setpoint to have Priority 0.5 in
Priority 0.5
the Priority Chart (fig. 7R) (°C)
(Ref. E pic. 7R)
Delta Room
Value of Delta from room
Setpoint
76
Setpoint to have Priority 1 in
Priority 1 (Ref.
the Priority Chart (fig. 7R) (°C)
F pic. 7R)
Delta
When Eco is Active, descrease
Temperature
77
the water setpoint temperature
for Sanitary
by this value (°C)
ECO mode
Force the Sanitary Electric
Heater to turn ON till the
Sanitary Water
Sanitary Water Setpoint is
78
Booser
reached.
0. Off
1. On
Time in minutes to wait to turn
Boiler Delay
on the boiler if the Sanitary
79
Time
Priority doesn't decrease. Set 0
to disable Boiler
Set the Boiler position in the
hydroulic circuit
0. Boiler before tank. The
switching valve is between
80
Boiler in Tank
boiler and Comfort Module
1. Boiler in tank. Boiler is
connected to Comfort Module
(no Valve between Tank and
Boiler)
Define the Sanitary/Pool Valve
Valve after
position in the hydronic circuit
81
Tank
0. Valve before tank
1. Valve after tank
Description
Master
Domestic hot water
x
x
x
x
x
x
x
x
x
x
x
Available on
User
Heat
Slave Pool
Interface
Pump
x
x
x
x
RANGE
MIN
MAX DEFAULT
1
2
3
40
80
55
5
15
5
5
15
5
1
5
1
1
5
1
0
10
5
0
1
0
0
180
15
1
1
19
80HMA

Publicité

Table des Matières
loading

Table des Matières