5. INSTALL FAUCET TRIM
Ensure valves are closed (cold fully counterclockwise, hot
fully clockwise).
Ensure main water supply is off.
NOTE: Keep spout supply tube clean above the finished
surface.
Place ring of plumbers putty or other sealant around
underside of spout according to the putty manufacturer's
instructions.
Slide spout partially down over spout supply tube. Align
anti-twist stud in drilled hole. Push down until spout
contacts deck.
NOTE: Do not cut O-ring on spout sleeve assembly.
Position spout and tighten setscrew.
6. INSTALL HANDLE ADAPTERS (ALL INSTALLATIONS)
Ensure valves are closed (cold fully counterclockwise, hot
fully clockwise).
Ensure main water supply is off.
Remove cardboard plaster guards from both sidebody
extensions.
A
1011145-2-
CLOSE
HOT
Setscrew
Spout Supply Tube
Spout Sleeve
Assembly
Close Hot
7
CLOSE
COLD
Fig. #13
Anti-twist
Screw
O-Ring
Fig. #14
Close
Cold
Fig. #15
Kohler Co.