Télécharger Imprimer la page

De Dietrich RCI 300 Instructions Techniques, D'installation Et D'entretien page 22

La station de neutralisation des condensats avec pompe

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
1.5 Electrical connections
1.5.1
Connection to an RCI
K control panel
- Take out the shunt (bridge). Connect to terminals 14-15 (CS).
- Connect the neutralisation station to a 230 V socket using the
connector provided.
1.5.2
Connection to a C 310 / C 610
- Take out the shunt (bridge). Connect to terminals L3-L2 (CS).
- Connect the neutralisation station to a 230 V socket using the
connector provided.
1.5.3
Connection - TC panel (For Germany only)
- Take out the shunt (bridge). Connect to the terminals 7-8.
- Connect the neutralisation station to a 230 V socket using the
connector provided.
6
DIEMATIC-m Delta control panel
- Take out the shunt (bridge). Connect to terminals 5-6 (CS).
- Connect the neutralisation station to a 230 V socket using the
connector provided.
DU15
04/12/2013 - 8541-4017-02