Electrical Issues (solid LED illuminated)

ENG
Problem
Display is blank or
frozen, the controller
will not accept
programming or is
operating abnormally.
Automatic error
detection indicates a
problem by ALARM LED
and an error message
on display.
LED is flashing or solidly
illuminated but I see no
message on the LCD.
34
ESP-Me Controller
Possible Cause
Power not reaching the
controller.
Controller needs to be reset. Press the Reset Button. For details see "Reset Button" section.
An electrical surge may
have interfered with the
controller's electronics.
Short circuit or overload
condition in valve, master
valve or pump start relay
wiring.
Dial not in AUTO RUN
position.
Possible Solution
Verify the main AC power supply is securely plugged in or
connected and working properly.
Unplug the controller for 2 minutes, then plug it back in. If there is
no permanent damage, the controller should accept programming
and resume normal operation.
Identify and repair the fault in the wiring. Refer to compatible
pump start relays. For details see "Connect Pump Start Relay"
section.
Turn dial to AUTO RUN position.