Low battery indication
Measurement Category
Overload protection
Agency approval
Safety compliance
Electromagnetic Compatibility
Size (H x W x L)
Weight
UAT-600-RE Receiver
Operating voltage
Tracing modes
Locating modes
Sensitivity adjustment
(gain control)
Depth measurement
Depth measurement accuracy
Sensitivity at 1 m (typical)
Display backlight
Audio indication
Compatible transmitter
Display
Update rate
Operating temperature and
humidity
Storage temperature and
humidity
Operating altitude
Pollution degree
IP-rating
Drop proof
�
CAT IV 600 V
600 V rms
Fuse FF 500 mA, 1000 V, IR 30 kA, Φ6.3×32 mm
�
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
IEC 61010-031, CSA/UL 61010-031 (test leads)
IEC 61326-1 Korea (KCC): Class A Equipment (Industrial Broadcasting &
Communication Equipment)
[1]
This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Approx. 355 x 230 x 120 mm (14 x 9 x 4.7 in)
Approx. 3.2 kg (7.0 lb) (batteries installed)
0 to 600 V
Active tracing: 33 kHz (32,768 Hz) and 8 kHz (8,192 Hz)
Passive tracing: 50 / 60 Hz and Radio
Peak and Null
Yes
Up to 6 m (20 ft)
0.1 m (4 in) to 3m (10 ft): ± 3 %
3 m (10 ft) to 6 m (20 ft): ± 5 %
Power: 2 mA
Radio: 20 µA
8 kHz: 5 µA
33 kHz: 5 µA
Automatic
Increasing closer to the signal
UAT-600-TE Transmitter
109 mm (4.3 in), 320 x 240 BW outdoor LC-Display with auto backlight
Instantaneous
-20 °C to 50 °C (-4 °F to 122 °F), ≤90% RH
-40 °C to 60 °C (-40 °F to 140 °F), ≤90% RH
< 2000 m (< 6561 ft)
2
IP54
1 m (3.28 ft)
23
[1]