6. SPECIFICATIONS
UAT-600-TE Transmitter
Operating voltage
Transmitting frequency
Transmitting mode power
output
Output voltage
Output current
Mains voltage measurement
Resistance measurement
(De-energized circuit)
Output hazardous voltage
warning
Mains hazardous voltage
warning
Audio indication
Compatible receiver
Compatible accessories
Display
Update rate
Operating temperature and
humidity
Storage temperature and
humidity
Operating altitude
Pollution degree
IP-rating
Drop proof
Power supply
Auto power off
Battery life
0 to 600 V
Energized circuit
Induction mode: 33 kHz (32,768 Hz)
Direct connection modes: 8 kHz (8,192 Hz) and 33 kHz (32,768 Hz)
Clamp mode: 8 kHz (8,192Hz) / 33 kHz (32,768Hz)
De-Energized circuit
Induction mode: 33 kHz (32,768 Hz)
Direct connection modes: 8 kHz (8,192 Hz), 33 kHz (32,768 Hz), A-Lo/A-Hi
A-Frame: 8 kHz (8,192 Hz)
Clamp mode: 8 kHz (8,192Hz) / 33 kHz (32,768Hz)
Max. 3 watts
Max. 50 V rms
Max. 250 mA rms, constant current in 5 steps
0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: ± 10%
0 Ω to 999 kΩ
Range: 0 Ω to 999 Ω (resolution: 5 Ω)
Range: 1 kΩ to 999 kΩ (resolution: 1 kΩ)
Accuracy: ± 10%
≥ 30 V rms
Icon displayed on screen: Tx
≥ 30 V rms
Red light indicator:
Fast beeps showing the better signal is applied
UAT-600-RE Receiver
SC-600-EUR Signal Clamp
AF-600-EUR A-Frame
TL-UAT-600 Test Lead Set
Monochrome dot matrix graphic LC-Display (LED backlight)
60 mm x 32 mm (2.4 in x 1.3 in)
Current (mA): 10 ms
Voltage (V): 15 ms
Resistance (Ω): 330 ms
-20 °C to 50 °C (-4 °F to 122 °F), ≤90% RH
-40 °C to 60 °C (-40 °F to 140 °F), ≤90% RH
< 2000 m (< 6561 ft)
2
IP54
1 m (3.28 ft)
Eight (8) 1.5 V D cell alkaline batteries
None
Approx. 16 hours at 21 °C (70 °F) (Typical)
22
�