Receiver Display
The Receiver display features a high-contrast, sunlight-optimized black and white LCD screen. It also has an
auto-backlight feature that activates in dark areas for optimized viewing.
2
1
6
Left-Right Arrows
These arrows indicate distance from the position of the cable. Both left and right arrows will appear when
exactly above the cable.
A solid arrow indicates that you are very close to or at the cable location.
A heavily shaded arrow indicates that you are approaching the cable location.
A lightly shaded arrow indicates that you are far from the cable location.
Receiver Setup
Set-up the Receiver before use by switching the unit on and pressing
the "ENTER/MENU" button. The Settings Menu display will appear.
• Use the "
/
" buttons to scroll up and down the menu.
• Press "ENTER" to change the setting of a feature.
• To exit, scroll down to "Exit" and press "ENTER".
From the Settings Menu, it is possible to select:
1. Antenna configuration –
2. Measurements – Imperial (0 '00") or Metric (0.00 m)
3. Locating frequency for Power Mode – 50 Hz or 60 Hz
Note: Some selections may not be available in all modes. If not available, the icon will be replaced by a ——.
Antenna Configurations
Peak signal with left/right arrows. This configuration is satisfactory for general
purpose locating.
Null signal with left/right arrows. This configuration gives a sharp Null signal over
the line but is less accurate than when in Peak Mode. Is useful for tracing long lines
as the sharp Null signal is easy to trace.
3
4
5
500
7
8
9
Peak or
Null
6
1
Speaker Volume
2
Locate Mode Indicator
Signal Level – Peak Indicator
3
Signal Level – Number Display
4
(0-999 relates to 0-99.9%)
5
Battery Status Indicator
Signal Locating Frequency
6
7
Left-Right Arrows
8
Signal Level – Bar Graph
9
Sensitivity Setting Indicator
0.00m
0'00''
50Hz
60Hz
Exit
Enter