Reset After Lockout - Safety Air Pressure Switch; Shut Down - Mi-T-M Corporation MH-0125-0MIH Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RESET AFTER LOCKOUT – SAFETY AIR PRESSURE SWITCH
The heater is equipped with a Reset push button. When the heater locks out, the red lamp on the push but-
ton (number 2 below) lights up. In this case push the Reset button (see Troubleshooting) to restart the heater.
The heater is also equipped with an air pressure switch that controls the airflow pressure and locks the
heater out in the event of unit overheating. If this occurs, detect and eliminate the cause of overheating be-
fore using the heater again. Have the heater inspected by a qualified technician if required. See point above
for resetting.

SHUT DOWN

Set switch to "OFF" to shut the flame off. The fan will go on rotating for 1 min 45 sec to cool the heater
down. The fan motor will automatically stop at the end of the after cooling time, then the unit can be discon-
nected from mains.
NEVER DISCONNECT THE SUPPLY PLUG TO STOP THE HEATER WHILE IN OPERATION. THE
BIG AMOUNT OF HEAT PRODUCED COULD DAMAGE THE COMPONENTS: ALLOW COOLING
SEQUENCE TO TAKE PLACE.
14
OPERATION
1
2
3
4
Kerosene Portable Heaters Manual

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mh-0300-0mih

Table des Matières