AERASGARD
®
Schematic diagram
1 2 3 4
shield
ON
1 2 3 4 5 6
mode
shield
1 2 3 4
Sensor
Plug for
VOC
display
Plug for
Sensor
Sensor
PS
CO2
ON
DIP A
1 2 3 4 5 6 7 8
address
VOC
VOC
°C
r.H.
CO ² CO ²
offset
zero
Type ⁄ WG02
RCO2 - Modbus
RCO2-Modbus
RCO2-Modbus LCD
RLQ - CO2 - Modbus
RLQ-CO2-Modbus
RLQ-CO2-Modbus LCD
RFTM - PS - Modbus
RFTM-PS-Modbus
RFTM-PS-Modbus LCD
RFTM - CO2 - Modbus
RFTM-CO2-Modbus
RFTM-CO2-Modbus LCD
RFTM - CO2 - Modbus - P
RFTM-CO2-Modbus-P
RFTM-CO2-Modbus-P LCD
RFTM - LQ - CO2 - Modbus
RFTM-LQ-CO2-Modbus
RFTM-LQ-CO2-Modbus LCD
RFTM - LQ - PS - CO2 - Modbus
RFTM-LQ-PS-CO2-Modbus
RFTM-LQ-PS-CO2-Modbus LCD
Housing variant "P":
Note:
ACCESSORIES
KA2 -Modbus
Communication adapter (USB/RS485) for system connection
LA -Modbus
Line termination device (with terminating resistor) as an active bus termination
RFTM - LQ - PS - CO2 - Modbus
R xx - Modbus
Sensor
Plug for
VOC
display
Plug for
Sensor
Sensor
PS
CO2
DIP B
ON
DIP A
1 2 3 4 5 6 7 8
address
°C
r.H.
VOC
CO ² CO ²
offset
zero
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
1 2 3 4
Measuring Range
Humidity
Temperature
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
0...100 % r.H.
0...+50 °C
Room control unit with potentiometer (standard printing is a widening arrow with central position unfilled)
These units must not be used as safety-relevant devices!
Schematic diagram
(with Potentiometer)
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Button
1 2 3 4
VOC
Plug for
display
shield
Sensor
CO2
ON
DIP B
ON
DIP A
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
zero
PM
CO2
5000 ppm
5000 ppm
5000 ppm
5000 ppm
0...1000 µg/m
3
0...1000 µg/m
3
5000 ppm
5000 ppm
5000 ppm
5000 ppm
5000 ppm
5000 ppm
0...1000 µg/m
3
5000 ppm
0...1000 µg/m
3
5000 ppm
15
Plug for
display
shield
Sensor
CO2
ON
DIP B
ON
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
DIP A: Bus address
Sensor
DIP B: Bus parameters
VOC
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Button
LED (internal status)
Potentio-
meter
Display
Item No.
VOC
=
P
1501-61B0-6001-200
1501-61B0-6021-200
0...100 %
1501-61B1-6001-500
0...100 %
1501-61B1-6021-500
1501- 2116-6001- 200
1501-2116 -6021- 200
1501-61B6-6001-200
1501-61B6-6021-200
1501-61B6-6501-271
1501-61B6-6521-271
0...100 %
1501-61B8-6001-500
0...100 %
1501-61B8-6021-500
0...100 %
1501- 2119-6001- 500
0...100 %
1501-2119 -6021- 500
1906- 1200- 0000-100
1906-1300- 0000- 100
Rev. 2022 - V31
RFTM - CO2 - Modbus - P
Sensor
VOC
DIP A
Potentio-
meter
zero
D
D
(B
Te
R
E
Sh
B
L