VR9205Q
Direct Ignition Combination
2-Stage Gas Controls
APPLICATION
The VR9205Q Direct Ignition Combination 2-Stage Gas
Controls are used in gas-fired appliances with up to 140
KBtu/h capacity at 1 in. wc pressure drop. They have
been optimized for direct ignition applications and include
Size Inlet-
Model
Outlet (in.)
VR9205
1/2 x 1/2
a
Capacity based on 1000 Btu/ft
at 0.25 kPa pressure drop).
b
Minimum regulation rated at high fire. Low fire regulation minimum based on outlet pressure is approximately 8 KBtu/h.
Table 2. Model Number Suffix Letter Designation.
Model Number
Suffix Letter
Q
SPECIFICATIONS
Body Pattern: Straight through; see Table 1 for inlet and
outlet size.
Electrical Ratings:
Voltage and Frequency: 24 Vac, 50/60 Hz.
Current Draw: Low Stage energized, 0.4A; High Stage
energized, 0.5A.
Capacity: See Table 1.
Regulation Range: See Table 1.
Table 3. Natural-LP Gas Conversion Kits.
Model Number Suffix
Letter
Q
Table 1. Valve Capacity.
AGA Certified
Capacity
KBtu/h
140
3
, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m
Ambient Temperature
Range
-40°F to 175°F
(-40°C to +79°C)
Kit to Convert Natural
Gas to LP
50033841
INSTALLATION INSTRUCTIONS
a manual switch, two automatic operators and a pressure
regulator. The valve may be used on either natural gas or
LP gas applications.
• Valve capacities are shown in Table 1.
• For suffix letter designation, see Tables 2 and 3.
a
AGA Certified Minimum
b
Regulation
KBtu/h
20
Pressure Regulator
Type
Two-Stage
Natural-LP Gas Conversion Kits: See Table 3.
6 in. Wire Harness: 50045486-001.
Gas valve end: Tyco Mate-N-Lok consisting of the
following:
Housing: Tyco 172166-1.
Pins: Tyco 770904-1 or 770988-1.
Control end: 3/8 in. stripped leads.
Approvals:
CSA Design Certificate # 158158
Kit to Convert LP to
Natural Gas
50033842
AGA Certified Maximum
Regulation
KBtu/h
200
3
, 0.64 sp gr natural gas
Place Bar Code Here
69-2143EF—01