The SIMPLE-RI control unit can be used to control 1 motor with power not exceeding 750W.
a) The wire connections and the operating logic should be in compliance with regulations in
force.
b) The cables featuring different voltage should be physically separated, or adequately insulated
by an additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f) Normally Closed inputs which are not in use should be short-circuited.
Terminal No. Function
1-2
Power supply Input, 230Vac 50Hz (1-Phase/2-Neutral)
3-4-5
Motor
6
COM
7-9
OPEN
8-10
CLOSE
9-6
SWO
10-6
SWC
11-12
24 Vac
13-14
Aerial
J3
Radio receiver
*IMPORTANT:
The RR.2WIV-SIMPLE receiver is specially designed for use with SIMPLE/SIMPLE-RI control
modules. It can only be used with 433.92MHz rolling-code transmitters.
An automatic running mode is enabled by the receiver. Every time the transmitter button is
pressed, the control module will execute the following commands in cycle: OPEN>>STOP>>CL
OSE>>STOP>>OPEN>>...etc.
Both DIP-SWITCHES in the SIMPLE control module should be left in the ON position
6
SIMPLE-RI Control Unit
GENERAL WARNINGS
INPUT/OUTPUT FUNCTIONS
Description
Connection to motor : (3-move/4-Com/5-move)
Common, Limit switch.
Input, OPEN push button (N.O. contact)
"Semi-Automatic" operation. Only when opening limit switches
are provided.
The operation starts when the OPEN push button is pressed, it
continues when the button is released and ends when the open-
ing limit switch is triggered.
You can stop the opening movement by briefly pressing the
CLOSE button.
Input, CLOSE push button (N.O. contact)
"Semi-Automatic" operation. Only when closing limit switches
are provided.
The operation starts when the CLOSE push button is pressed, it
continues when the button is released and ends when the closing
limit switch is triggered.
You can stop the closing movement by briefly pressing the OPEN
button.
Input, OPENING limit switch (N.C. contact)
Input, CLOSING limit switch (N.C. contact)
Output, power supply of accessories, 24Vac/100 A max.
Connection of aerial, insertable radio receiver card (13-signal/14-
screen)
Insertable connector for RR.2WIV-SMPLE*, two-channel radio
receiver

Publicité