Télécharger Imprimer la page

Faber STILO Serie Instructions D'installation page 8

Publicité

Les langues disponibles

Les langues disponibles

1. LOWER CHIMNEY DUCTLESS
2. LEFT VENT GRID
3. RIGHT VENT GRID
4. DIVERTER EXTENSION HORIZONTAL (2 PIECES)
5. DUCTLESS DIVERTER
6. CHARCOAL FILTER
FIGURE 8
FOR DUCTLESS INSTALLATIONS
Ductless installations require a Ductless Conversion Kit
whose components are pictured in FIGURE 8. Do not use
the DAMPER (H in FIGURE 1) for ductless installations.
The LOWER CHIMNEY COVER (B in FIGURE 1) should
be discarded and replaced by a new one with holes (1 in
FIGURE 8).
1. As indicated in FIGURE 8, fit the DUCTLESS DIVERTER
(5) over the duct outlet. Fit the 2 DIVERTER EXTENSION
HORIZONTAL pieces (4) on either side of the DUCTLESS
DIVERTER.
2. Install the CHARCOAL FILTER (6) behind the center grease
filter opening by inserting and locking into place, as indicated
in FIGURE 9.
FIGURE 9
FOR ALL INSTALLATIONS
1. Remove the cover from the Field Wiring Compartment with a
phillips screwdriver. Feed the Power Supply Cable through the
electrical knockout. Connect the Power Supply Cable to the range-
hood cable. Attach the Power Supply Cable grounding lead to the
green screw provided. Attach the White lead of the power supply
to the White lead of the rangehood with a twist-on type wire con-
nector. Attach the Black lead of the power supply to the Black lead
of the rangehood with a twist-on type wire connector. Using the 4
holes provided screw the Field Wiring Compartment to the wall as
dictated by your Power Supply Cable location (screws not provided).
Replace the cover.
2. Install the UPPER CHIMNEY COVER (C in FIGURE 10) by slightly
widening the two sides and hooking them behind the CHIMNEY
MOUNTING BRACKETS (E). Secure the sides to the CHIMNEY
MOUNTING BRACKETS with the 4 CHIMNEY SCREWS (G).
3. Install the LOWER CHIMNEY COVER (B) by slightly widening
the two sides of the LOWER CHIMNEY COVER and hooking them
between the UPPER CHIMNEY COVER and the wall making sure
that it fits snugly. Secure the LOWER CHIMNEY COVER to the
CANOPY SECTION (A) with 2 CHIMNEY SCREWS (G).
FOR DUCTLESS
INSTALLATIONS
Fit the LEFT AND RIGHT
VENT GRIDS (2 and 3)
into the LOWER CHIMNEY
DUCTLESS holes, making
sure that the directional
symbols are towards the top
and front of the hood and that
they connect snugly to the
DIVERTER EXTENSION
HORIZONTAL pieces.
FIGURE 10
FIGURE 11
Version 04/05 - Page 8

Publicité

loading