Technical data
Transmitter TX / Receiver RECV
Signal
Max. input voltage
Operating conditions
Storage conditions
Transmitter TX
Max. output current
Max. signal voltage
Max. testing length
Power supply
Dimensions
Weight
Receiver RECV
Max. output current
SCAN mode measuring
range
Power supply
Dimensions
Weight
Subject to technical alterations. 19W19
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies)
before storing for longer periods. Store the device in a clean and
dry place.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AAW
CableChecker
Multi-frequency pulse
20 V DC
-10°C ... 40°C, max. humidity
85% rH, no condensation,
max. working altitude 2000 m
above sea level
-10°C ... 50°C, max. humidity
85% rH, no condensation
10 mA
8 Vss (peak-to-peak)
100 m
2 x 1,5V LR03 (AAA)
80 x 152 x 46 mm
185 g (incl. batteries)
30 mA
0 - 5 cm measuring depth
4 x 1,5V LR44 (AG13)
26 x 148 x 17 mm
45 g (incl. batteries)