If you want to alter the standard setting, first pull the plug out of the wall outlet and then
remove the device cover and configure the device according to the following directions:
IN1
K1 K2
Fig. Jumper positions
Jumper
Function
IN1
K1 / K2
Phantom voltage IN1*
K3
Sensitivity IN1
IN2
K4
Sensitivity IN2
K5 / K6
Phantom voltage IN2*
IN3
-
-
* With phantom voltage switched on, a microphone or a Line-IN device should not be con-
nected with the asymmetrical jack; this could otherwise result in damage to the device.
K3
IN2
K4
K5K6
Open
Off
microphone
microphone
Off
-
Closed
Default
setting
On
On
Line IN
microphone
Line IN
Line IN
On
Off
-
-
IN3