6.2. Conditions of use

• The temperature must not move outside the
application temperature range of –40 °C to +80 °C.
• The load capacity as specified in the technical data
must not be exceeded.
• The swivel is rotatable below the maximum load
capacity.
• The swivel can be blocked by two grub screws.
• Not suitable for underwater use.
• No lateral forces and/or parallel shear pull > 2°
caused by the rope may act on the PFEIFER Swivel.
NOTE!
According to ISO 16625, Annex B, chapter
B.4, the maximum parallel shear pull for
extremely rotation­free ropes may not
exceed 2°.
• Sudden stresses must be avoided.
• The swivel as part of the load lifting attachment is
not designed for the transport of loads above people.

6.3. Lubricant recommendation

The PFEIFER Swivel PSH TSS is lubricated as standard
with Gleitmo 585M. Gleitmo 585M is a high­grade
lithium­soap paste on a mineral oil basis. Do not mix
with greases with a different soap basis. Safety data
sheet available on request.
For trouble­free operation of the swivel, it is recom­
mended to re­lubricate the swivel via the grease nipple
with Gleitmo 585M. It is not advisable to use a different
lubricant.
Properties of Gleitmo 585M
• provides extensive protection against wear and tear –
even with shock load and oscillatory movement
• reduces fretting corrosion
• provides excellent corrosion protection
• permits long lubrication intervals
• very resistant to ageing
• permits heavy­duty machines and systems
to function reliably
Technical data: Gleitmo 585M
Description
Value
Colour
beige
Operating
temperature
–25/+120
range
Base oil
min
Thickener
Li
The guidelines for the cargo lashing must be adhered to
when transporting in a vehicle. Manual lifting of heavy
loads from 20 kg (men) or 8 kg (women) should be
avoided as far as possible. Aids should be used if
possible.
• Prior to the assembly, the housing, the collar bolt
Unit
Regulation
°C
LV0124
Description
Value
Base oil vis­
100
cosity [40 °C]
Work resistance/penetration reduction after:
10,000
ca. 15
double strokes
100,000
max. 30
double strokes
NLGI class
2
Dropping point
≥170
Water
1­90
resistance
Flow pressure
ca. 78
[20 °C]
Flow pressure
ca. 350
[–10 °C]
Flow pressure
ca. 1000
[–20 °C]
EMCOR
0/1
[distilled water]
Four ball
5500/6000
welding load
Almen­Wieland
> 18
fretting load
Friction
ca. 0,10
coefficient
FAG­FE9 test
run A/1500/
> 300
6000­120 F50

7. Transport

8. Assembly and installation
instructions
including the safety linch pin (Swivel PSH TSS) or
cotter pin (Swivel PSH civil engineering), the lock
washer (Swivel PSH civil engineering), the centring
sleeve (Swivel PSH civil engineering So) and the
protective bushing (Swivel PSH civil engineering So)
must be checked for visible damage, e. g. cracks,
corrosion, deformation. etc.
Unit
Regulation
mm²/s
DIN 51562­1
1/10 mm
1/10 mm
DIN 51818
°C
DIN ISO 2176
rating
DIN 51807­1
hPa
DIN 51805
hPa
DIN 51805
hPa
DIN 51805
rating
DIN 51802
N
DIN 51350­4
kN
LV0029
LV0029
h
DIN 51821
Swivel 09/2021 / Subject to change !