that the relief valve and the electrical system are able to support the load of the appliance (see
the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, "standardised"
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into contact with hot
parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable power
outlet.
For appliances that come supplied with cable and plug please ensure they are plugged into a
circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not observed.
E
RANGE HOOD WITH OUTSIDE DISCHARGE
In this version, the fumes and steam from the kitchen are conveyed outside through an ex-
haust duct.
The exhaust conveyor that protrudes from the upper part of the range hood must be con-
nected to a duct that carries the fumes and steam outside. In this version, the charcoal filters,
if fitted, should be removed; to do this, see the instructions in point F. There must be adequate
ventilation of the room when the range hood is used at the same time as appliances burning
gas or other fuels, according to the standard.
Deviation for Germany:
When the range hood and appliances supplied with energy other than electricity are simulta-
neously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).
F
RECIRCULATING RANGE HOOD
Hood not designed for charcoal filters.
G
ELECTRONIC CONTROL FUNCTIONING
KEY 1
Timer:
When the motor is running, pressing this key will activate the timer for the motor to shut-down
after 15 minutes. Key 1 flashes to indicate that the function is active. The motor and light switch
off after 15 minutes.
The countdown does not stop if the motor speed is changed. If the motor is stopped with
key 2, the function will automatically deactivate. When the timer function is active, it can be
deactivated by pressing key 1.
Opening the mobile part (assistance mode):
When all the LEDs on the keyboard are switched off (light and motor off ), pressing and holding
the key will allow you to open the mobile part of the range hood for maintenance operations.
In this state, the motor cannot be activated. Keys T2..T5 are inhibited.
Closing the mobile part (assistance mode):
To close the mobile part in assistance mode (door open and motor off ) press and hold key 1.
Keys T2..T5 will start working again.