General Application
These trims are for use with the GrohFlex
valve.
Planning of piping is done at the time of the rough installation.
3 different types of thermostat mixers are possible.
Observe the possible combinations, see Pages 1 and 2.
Specification
• Integral service stops
• Flow pressure:
- min
- recommended
greater than 5 bar or 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Max. test pressure
1
3
3
English
TM
universal rough-in
1 bar or 14.5 psi
1-5 bar or 14.5 – 72.5 psi
8.5 bar or 125 psi
34.5 bar or 500 psi
• Flow rates at 3 bar or 45 psi
- Type #1 (19 848) and Type #2 (19 849)
bottom outlet
top outlet
- Type #3 (19 865)
• Temperature
- max. (hot water inlet)
• Water connection:
General preparation
1. Cut of the excess blue box material, see Fig. [1].
2. Seal the rough-in valve, see Fig. [2].
3. Close the integrated service stops, see Fig. [3].
4. Remove flush cap, see Fig. [4].
2
4
24 l/min or 6,3 gpm
12 l/min or 3,2 gpm
51 l/min or 14 gpm
80 °C or 180 °F
cold - RH
hot - LH

Publicité